Tomography Jobs: Tilt-series Processing and Reconstruction
Tomography jobs from tilt-series import through alignment, reconstruction and denoising
This page covers the complete set of tomography job types in CCPEM-Pipeliner, from importing raw tilt-series images through motion correction, CTF estimation, tilt-series alignment, tomogram reconstruction, and denoising. Tomography workflows in pipeliner are represented as directed graphs of specialised jobs that track tilt-series metadata through each processing stage in a reproducible, auditable way. Understanding the exact process names, required inputs, key options, and external programs for each job type lets you build robust automated pipelines — either via the Python API or from the command line — that can run headlessly at facilities or on HPC clusters.
Tomography jobs follow a strict data-flow order. Each job consumes a TiltSeriesGroupMetadata or TomogramGroupMetadata node produced by the previous step and emits a new node that the next job can consume. The registered tomography job types, in workflow order, are:
| Process name | Class | Output |
|---|---|---|
relion.importtomo | RelionImportTiltSeriesMovies | tilt_series.star |
relion.importtomo.coordinates | RelionImportCoordinates | particles.star |
relion.motioncorr.tomo.own | TomoRelionMotionCorrOwn | corrected_tilt_series.star |
relion.motioncorr.tomo.motioncor2 | TomoRelionMotionCorrMotionCor2 | corrected_tilt_series.star |
relion.ctffind.tomo.ctffind4 | TomoRelionCtfFindCtffind4 | tilt_series_ctf.star |
relion.excludetilts | RelionExcludeTiltSeries | selected_tilt_series.star |
relion.aligntiltseries.aretomo | AreTomoJob | aligned_tilt_series.star |
relion.aligntiltseries.imod_fiducial | ImodAlignFiducialJob | aligned_tilt_series.star |
relion.aligntiltseries.imod_patchtrack | ImodAlignPatchTrackJob | aligned_tilt_series.star |
relion.reconstructtomograms | RelionTomoReconstructJob | tomograms.star |
relion.joinstar.tomograms | RelionJoinStarTomograms | merged_tomograms.star or merged_tilt_series.star |
relion.denoisetomo | RelionDenoiseJob | tomograms.star |
relion.denoisetomo.train | RelionDenoiseTrainJob | denoising_model.tar.gz |
All tomography jobs run against a pipeliner project in the current working directory. The typical sequence is:
- Import tilt series with
relion.importtomo. - Correct beam-induced motion with
relion.motioncorr.tomo.ownorrelion.motioncorr.tomo.motioncor2. - Estimate CTF with
relion.ctffind.tomo.ctffind4. - Optionally exclude bad tilts with
relion.excludetilts. - Align tilt series with one of the three alignment jobs.
- Reconstruct tomograms with
relion.reconstructtomograms. - Optionally train and apply a denoiser with
relion.denoisetomo.trainthenrelion.denoisetomo.
Generating and editing a run.job file (CLI)
Generate a default parameter file for any tomography job:
pipeliner --default_runjob relion.importtomo
# writes relion_importtomo_run.job
Edit the file (it uses label == value format), then schedule and run it:
pipeliner --run_job relion_importtomo_run.job
To continue a job that supports continuation (e.g. relion.motioncorr.tomo.own, relion.reconstructtomograms):
pipeliner --continue_job MotionCorr/job002/
Key option keys by job
relion.importtomo — required options:
fn_in_raw— tilt image file glob (e.g.frames/*.tif)fn_mdoc— mdoc file globangpix— pixel size in ÅkV— voltage in kVCs— spherical aberration in mmQ0— amplitude contrastdose_rate_pertilt— dose per tilt image (e/Ų)tilt_angle— nominal tilt axis angle in degrees
Optional: optics_gp_name, prefix, mtf_file, is_motion_corrected, is_doserate_per_frame, do_invert_hand.
relion.motioncorr.tomo.own / relion.motioncorr.tomo.motioncor2 — required options:
input_star_mics— input tilt series STAR file (TiltSeriesGroupMetadata)eer_grouping,bfactor,patch_x,patch_y,group_frames,bin_factor
The relion.motioncorr.tomo.motioncor2 variant requires the MotionCor2 executable (default MotionCor2, overridable via PIPELINER_MOTIONCOR2_EXECUTABLE or RELION_MOTIONCOR2_EXECUTABLE). Both variants support continuation (can_continue=True) and append --only_do_unfinished when continued. do_float16 defaults to True on the own implementation.
relion.ctffind.tomo.ctffind4 — required option:
input_star_mics— input tilt series STAR file
use_given_ps (default Yes) must stay Yes if the upstream motion correction used do_float16=Yes (the default).
Key options inherited from the SPA CTF job: box, resmin, resmax, dfmin, dfmax, dfstep, dast, do_phaseshift. Additional tomo-specific options: localsearch_nominal_defocus, exp_factor_dose, slow_search.
Requires relion_run_ctffind, which is passed --ctffind_exe ctffind (default, overridable via PIPELINER_CTFFIND_EXECUTABLE / RELION_CTFFIND_EXECUTABLE). Supports continuation (can_continue=True) and appends --only_do_unfinished when continued.
relion.excludetilts — required options:
in_tiltseries— input tilt series STAR file with CTF informationcache_size— number of tilt series to cache in memory (default 5)
Requires relion_python_tomo_exclude_tilt_images.
relion.aligntiltseries.aretomo — required options:
in_tiltseries— input tilt series STAR filetomogram_thickness— estimated thickness in nm (default 300)
Optional: do_aretomo_tiltcorrect, aretomo_tiltcorrect_angle, do_aretomo_ctf, do_aretomo_phaseshift, other_aretomo_args, gpu_ids.
Requires relion_align_tiltseries and AreTomo2 (default, overridable via PIPELINER_ARETOMO_EXECUTABLE / RELION_ARETOMO_EXECUTABLE).
relion.aligntiltseries.imod_fiducial — required options:
in_tiltseries— input tilt series STAR filefiducial_diameter— fiducial diameter in nm (default 10)
Requires relion_align_tiltseries and batchruntomo (default, overridable via PIPELINER_BATCHTOMO_EXECUTABLE / RELION_BATCHTOMO_EXECUTABLE).
relion.aligntiltseries.imod_patchtrack — required options:
in_tiltseries— input tilt series STAR filetomogram_thickness— estimated thickness in nmpatch_size— patch size in nmpatch_overlap— patch overlap percentage
Requires relion_align_tiltseries and batchruntomo.
relion.reconstructtomograms — required options:
in_tiltseries— aligned tilt series STAR filewidth,height,thickness— unbinned tomogram dimensions in pixelsbinned_pixel_size— output binned pixel size in Å
Optional: do_need_denoising (generate split tomograms for denoising), do_write_centralslices, do_fourierinversion_filter, ignore_ctf, only_this_tomo, tilt_angle_offset.
Supports continuation (can_continue=True). Requires relion_tomo_reconstruct_tomogram.
relion.joinstar.tomograms — requires at least two inputs in either input_tomo_files (tomogram STAR files) or input_ts_files (tilt series STAR files), but not both simultaneously. Validates that at least 2 files are present at scheduling time; column/block mismatch is detected at execution time. Optional: remove_duplicates (default True).
relion.denoisetomo.train — required options:
cryocare_path— directory containing cryoCARE executablesin_tomoset— tomograms STAR file (must have half-tomogram columns)tomograms_for_training— list of tomogram names (multistring,:::separated)subvolume_dimensions— sub-volume side length in pixelsgpu_ids— single GPU ID (e.g.0)
Only a single GPU may be used. Requires relion_python_tomo_denoise.
relion.denoisetomo — required options:
cryocare_path— directory containing cryoCARE executablesin_tomoset— tomograms STAR file with half-tomogram columnscare_denoising_model— path to.tar.gzmodel from arelion.denoisetomo.trainjobntiles_x,ntiles_y,ntiles_z— number of tiles per dimension (minimum 2)gpu_ids— single GPU ID
Requires relion_python_tomo_denoise.
Continuation support
The following tomography jobs have can_continue=True:
relion.motioncorr.tomo.ownrelion.motioncorr.tomo.motioncor2relion.ctffind.tomo.ctffind4relion.reconstructtomograms
The import, alignment, exclude-tilts, join-star, and denoising jobs do not support continuation.
Example 1 — Import a tilt-series dataset
Import raw tilt images and their SerialEM mdoc files into a new project. The job outputs tilt_series.star (a NODE_TILTSERIESGROUPMETADATA node).
import os
from pipeliner.api.manage_project import PipelinerProject
os.chdir("/data/my_tomo_project")
proj = PipelinerProject(make_new_project=True)
import_job = proj.run_job(
{
"_rlnJobTypeLabel": "relion.importtomo",
"fn_in_raw": "frames/*.tif",
"fn_mdoc": "mdoc/*.mdoc",
"angpix": "1.35",
"kV": "300",
"Cs": "2.7",
"Q0": "0.1",
"dose_rate_pertilt": "3.0",
"tilt_angle": "84.1",
"is_motion_corrected": "false",
},
run_in_foreground=True,
)
print(import_job.output_dir) # Import/job001/
Example 2 — Motion-correct the tilt series (RELION's own algorithm)
The relion.motioncorr.tomo.own job requires relion_run_motioncorr and reads the tilt_series.star produced by the import job. It outputs corrected_tilt_series.star.
motioncorr_job = proj.run_job(
{
"_rlnJobTypeLabel": "relion.motioncorr.tomo.own",
"input_star_mics": "Import/job001/tilt_series.star",
"bfactor": "150",
"patch_x": "1",
"patch_y": "1",
"bin_factor": "1",
"eer_grouping": "32",
"do_even_odd_split": "true", # required for later denoising
"nr_mpi": "4",
},
run_in_foreground=True,
)
To continue an unfinished run (for example after adding new movies), edit continue_job.star in the job directory and call:
proj.continue_job(motioncorr_job.output_dir, run_in_foreground=True)
Both relion.motioncorr.tomo.own and relion.motioncorr.tomo.motioncor2 append --only_do_unfinished automatically when is_continue=True.
Example 3 — Estimate CTF for each tilt
The relion.ctffind.tomo.ctffind4 job wraps relion_run_ctffind and CTFFIND4 (executable resolved from PIPELINER_CTFFIND_EXECUTABLE or RELION_CTFFIND_EXECUTABLE, default ctffind). It reads the corrected tilt-series STAR file and outputs tilt_series_ctf.star.
ctf_job = proj.run_job(
{
"_rlnJobTypeLabel": "relion.ctffind.tomo.ctffind4",
"input_star_mics": "MotionCorr/job002/corrected_tilt_series.star",
"use_given_ps": "true",
"box": "512",
"resmin": "30",
"resmax": "5",
"dfmin": "5000",
"dfmax": "50000",
"dfstep": "500",
"dast": "100",
"localsearch_nominal_defocus": "10000",
"exp_factor_dose": "100",
"nr_mpi": "4",
},
run_in_foreground=True,
)
Example 4 — Align tilt series with AreTomo2
relion.aligntiltseries.aretomo requires both relion_align_tiltseries and AreTomo2 (resolved from PIPELINER_ARETOMO_EXECUTABLE or RELION_ARETOMO_EXECUTABLE, default AreTomo2). It outputs aligned_tilt_series.star.
align_job = proj.run_job(
{
"_rlnJobTypeLabel": "relion.aligntiltseries.aretomo",
"in_tiltseries": "CtfFind/job003/tilt_series_ctf.star",
"tomogram_thickness": "300",
"do_aretomo_tiltcorrect": "false",
"do_aretomo_ctf": "false",
"gpu_ids": "0",
"nr_mpi": "2",
},
run_in_foreground=True,
)
For IMOD fiducial-based alignment, use relion.aligntiltseries.imod_fiducial with the fiducial_diameter option (in nm). For IMOD patch-tracking, use relion.aligntiltseries.imod_patchtrack with patch_size and patch_overlap; both require batchruntomo (default batchruntomo, overridable via PIPELINER_BATCHTOMO_EXECUTABLE or RELION_BATCHTOMO_EXECUTABLE).
Example 5 — Exclude bad tilts interactively
relion.excludetilts launches a Napari-based UI. It is not recommended for remote sessions. It reads a tilt-series STAR file that already has CTF information.
exclude_job = proj.schedule_job(
{
"_rlnJobTypeLabel": "relion.excludetilts",
"in_tiltseries": "CtfFind/job003/tilt_series_ctf.star",
"cache_size": "5",
}
)
Run it in the foreground so the Napari window opens on your display:
proj.run_scheduled_job(exclude_job, run_in_foreground=True)
Example 6 — Reconstruct tomograms
relion.reconstructtomograms requires relion_tomo_reconstruct_tomogram. It outputs tomograms.star (a NODE_TOMOGRAMGROUPMETADATA node).
reconstruct_job = proj.run_job(
{
"_rlnJobTypeLabel": "relion.reconstructtomograms",
"in_tiltseries": "AlignTiltSeries/job005/aligned_tilt_series.star",
"width": "3838",
"height": "3710",
"thickness": "1200",
"binned_pixel_size": "10.0",
"do_need_denoising": "true", # generates half-tomograms for cryoCARE
"do_write_centralslices": "true",
"nr_mpi": "4",
"nr_threads": "4",
},
run_in_foreground=True,
)
Set do_need_denoising to true if you plan to run the cryoCARE denoising jobs; this instructs RELION to write even/odd half-tomograms alongside the full reconstruction.
Example 7 — Train a cryoCARE denoising model
relion.denoisetomo.train requires relion_python_tomo_denoise plus the cryoCARE executables directory (set via PIPELINER_CRYOCARE_EXECUTABLES_DIR). It outputs denoising_model.tar.gz (a NODE_MLMODEL node). Supply tomogram names as a list using the ::: separator for MultiStringJobOption values.
train_job = proj.run_job(
{
"_rlnJobTypeLabel": "relion.denoisetomo.train",
"cryocare_path": "/opt/cryocare/bin",
"in_tomoset": "Tomograms/job006/tomograms.star",
"tomograms_for_training": "TS_001:::TS_002:::TS_003",
"number_training_subvolumes": "1200",
"subvolume_dimensions": "72",
"gpu_ids": "0",
},
run_in_foreground=True,
)
Note: gpu_ids must be a single GPU identifier — spaces, colons, commas, and semicolons are rejected with a validation error.
Example 8 — Apply a trained denoising model
relion.denoisetomo reads the model produced by the training job and outputs tomograms.star with denoised reconstructions.
denoise_job = proj.run_job(
{
"_rlnJobTypeLabel": "relion.denoisetomo",
"cryocare_path": "/opt/cryocare/bin",
"in_tomoset": "Tomograms/job006/tomograms.star",
"care_denoising_model": "Denoise/job007/denoising_model.tar.gz",
"ntiles_x": "2",
"ntiles_y": "2",
"ntiles_z": "2",
"gpu_ids": "0",
},
run_in_foreground=True,
)
Example 9 — Join multiple tilt-series STAR files
relion.joinstar.tomograms can merge either tomogram or tilt-series STAR files. Supply at least two input files (checked at scheduling time). Files whose blocks or columns differ, such as a mix of tomogram and tilt-series files, are not rejected at scheduling time; the job fails at run time with ValueError('Star files have different blocks/columns').
join_job = proj.run_job(
{
"_rlnJobTypeLabel": "relion.joinstar.tomograms",
"input_ts_files": (
"AlignTiltSeries/job005/aligned_tilt_series.star"
":::AlignTiltSeries/job008/aligned_tilt_series.star"
),
"remove_duplicates": "true",
},
run_in_foreground=True,
)
Example 10 — Generate a default run.job file for CLI use
Use pipeliner --default_runjob to generate an editable parameter file, then submit it:
# Generate default parameter file
pipeliner --default_runjob relion.importtomo
# Produces: relion_importtomo_run.job
# Edit the file (labels must match exactly)
# Then schedule and run:
pipeliner --run_job relion_importtomo_run.job
run.job files use the <option_label> == <value> format. For example:
job_type == relion.importtomo
is_continue == false
is_tomo == true
Tilt image files: == frames/*.tif
mdoc files: == mdoc/*.mdoc
Pixel size (Angstrom): == 1.35
Voltage (kV): == 300
Spherical aberration (mm): == 2.7
Amplitude contrast: == 0.1
Dose rate per tilt-image: == 3.0
Tilt axis angle (deg): == 84.1